Fire resistance of buildings
Approved Document B Fire Safety, Volume 2, Buildings other than dwellinghouses (2019 edition), defines fire resistance as:
'The ability of a component or a building to satisfy, for a stated period of time, some or all of the appropriate criteria given in the relevant standard.'
Fire resistance is a measure of one or more of the following:
- Resistance to collapse (loadbearing capacity), which applies to loadbearing elements only, denoted R in the European classification of the resistance to fire performance.
- Resistance to fire penetration (integrity), denoted E in the European classification of the resistance to fire performance.
- Resistance to the transfer of excessive heat (insulation), denoted I in the European classification of the resistance to fire performance.
Fire resistance is measured in minutes. This relates to time elapsed in a standard test and should not be confused with real time.
Performance in terms of the fire resistance to be achieved by elements of structure, doors and other forms of construction is classified in accordance with BS EN 13501.
Other information about fire resistance in the approved document includes:
- Table B3 gives the specific requirements for each element of structure.
- Table B4 sets out the minimum periods of fire resistance for elements of structure.
- Table B5 sets out limitations on the use of uninsulated fire resisting glazed elements.
NB PAS 9980:2022, Fire risk appraisal of external wall construction and cladding of existing blocks of flats – Code of practice, published by BSI Standards Limited in 2022, defines fire resistance as the: ‘…ability of an item to fulfil for a stated period of time the required loadbearing capacity and/or integrity and/or thermal insulation, and/or other expected duty specified in a standard fire resistance test. NOTE This is not the time that the item can withstand exposure to any specific real fire without loss of its required performance.’
[edit] Related articles on Designing Buildings
- Adhesives.
- BS 476.
- BS EN 13501-1.
- Cavity barrier.
- Compartment floor.
- Dry riser.
- Escape route.
- Fire.
- Fire and rescue service.
- Fire blanket.
- Fire collar.
- Fire compartment.
- Fire damper.
- Fire detection and alarm systems.
- Fire door.
- Fire safety design.
- Fire-separating element.
- Fire separation.
- Fire-stopping.
- Firefighting route.
- Intumescent coatings.
- Intumescent strip.
- Joint fire code.
- Mastic asphalt flooring.
- Means of escape.
- Passive fire protection is a vital tool in any fire strategy.
- Place of special fire hazard.
- Protected escape route.
- Protected stairway.
- Sacrificial timber.
- Supporting construction.
- Thermoplastic material.
- Unprotected escape route.
- Wet riser.
Featured articles and news
What it is and how to use it.
Investors in People: CIOB achieves gold
Reflecting a commitment to employees and members.
Scratching beneath the surface; a guide to selection.
ECA 2024 Apprentice of the Year Award
Entries open for submission until May 31.
UK gov apprenticeship funding from April 2024
Brief summary the policy paper updated in March.
For the World Autism Awareness Month of April.
70+ experts appointed to public sector fire safety framework
The Fire Safety (FS2) Framework from LHC Procurement.
Project and programme management codes of practice
CIOB publications for built environment professionals.
The ECA Industry Awards 2024 now open !
Recognising the best in the electrotechnical industry.
Sustainable development concepts decade by decade.
The regenerative structural engineer
A call for design that will repair the natural world.
Buildings that mimic the restorative aspects found in nature.
CIAT publishes Principal Designer Competency Framework
For those considering applying for registration as a PD.
BSRIA Building Reg's guidance: The second staircase
An overview focusing on aspects which most affect the building services industry.
Design codes and pattern books
Harmonious proportions and golden sections.
Introducing or next Guest Editor Arun Baybars
Practising architect and design panel review member.
Comments